Tip
Need help? Please let us know in the SUEWS Community.
Please report issues with the manual on GitHub Issues (or use Report Issue for This Page for page-specific feedback).
Please cite SUEWS with proper information from our Zenodo page.
5.3.12. STEBBS Output Variables#
STEBBS model outputs (experimental).
This group contains 80 output variables.
- Kroof_in#
Incoming shortwave radiation on roof per surface area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Kwall_in#
Incoming shortwave radiation on wall per surface area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Lroof_in#
Incoming longwave radiation on roof per surface area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Lwall_in#
Incoming longwave radiation on wall per surface area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QBAE_bldg_FA#
Total heat transfer by air exchange per building footprint area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QEC_bldg_FA#
Total energy consumption and metabolism per building footprint area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QEC_cooling_FA#
Energy consumption by space cooling
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QEC_dhw_FA#
Energy consumption by dhw system
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QEC_heating_FA#
Energy consumption by space heating
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QH_appliance_FA#
Sensible appliance heat gain
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QH_bldg_FA#
Total convective heat transfer at external building surface per building footprint area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QH_metabolism_FA#
Sensible metabolic heat gain
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QH_ventilation_FA#
Heat gain/loss through ventilation
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_ground_FA#
Conductive heat through ground beneath building
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_groundflr_FA#
Conductive heat through floor
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_roof_FA#
Conductive heat through roof
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_tank_FA#
Conductive heat through water tank
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_vessel_FA#
Conductive heat through water vessel
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_wall_FA#
Conductive heat through wall
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHcond_window_FA#
Conductive heat through window
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_extroof_FA#
Convective heat between external roof and outdoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_exttankwall_FA#
Convective heat between external surface of tank and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_extvesselwall_FA#
Convective heat between external surface of vessel and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_extwall_FA#
Convective heat between external wall and outdoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_extwin_FA#
Convective heat between external window and outdoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_indoormass_FA#
Convective heat between internal mass and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_intgroundflr_FA#
Convective heat between internal surface of floor and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_introof_FA#
Convective heat between internal surface of roof and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_inttankwall_FA#
Convective heat between internal surface of tank and indoor water
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_intvesselwall_FA#
Convective heat between internal surface of vessel and water
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_intwall_FA#
Convective heat between internal surface of wall and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHconv_intwindow_FA#
Convective heat between internal surface of window and indoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHload_cooling_FA#
Sensible cooling load
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHload_dhw_FA#
Sensible heat supply to hot water tank
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHload_heating_FA#
Sensible heating load
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHwaste_cooling_FA#
Waste heat rejection from cooling system to outdoor air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHwaste_dhw_FA#
Sensible heat gain from waste heat due to hot water
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QHwaste_heating_FA#
Sensible heat gain from waste heat due to space heating
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QN_bldg_FA#
Net all-wave radiation per building footprint area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_air_FA#
Storage heat flux in air
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_bldg_FA#
Storage heat flux for building components
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_dhw_FA#
Storage heat flux in hot water going to drainage system
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_ground_FA#
Storage heat flux in the soil beneath building
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_groundfloor_FA#
Storage heat flux ground floor
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_indoormass_FA#
Storage heat flux in indoormass
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_roof_FA#
Storage heat flux in roof
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_total_FA#
Total Storage heat flux per building footprint area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_wall_FA#
Storage heat flux in wall
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QS_window_FA#
Storage heat flux in window
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- QWaste_bldg_FA#
Total waste heat from HVAC system to outdoor air per building footprint area
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qloss_drain_FA#
Heat loss from hot water to drainage system
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qlw_net_roof_FA#
Net longwave radiation from external surface of roof
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qlw_net_tank_FA#
Net longwave radiation from external surface of tank to internal mass
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qlw_net_vessel_FA#
Net longwave radiation from external surface of vessel to internal mass
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qlw_net_wall_FA#
Net longwave radiation from external surface of wall
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qlw_net_window_FA#
Net longwave radiation from external surface of window
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qsw_abs_roof_FA#
Shortwave radiation absorbed by roof
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qsw_abs_wall_FA#
Shortwave radiation absorbed by wall
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qsw_abs_win_FA#
Shortwave radiation absorbed by window
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Qsw_trans_win_FA#
Shortwave radiation transmitted through window
- Unit:
W m-2
- Aggregation:
Average (mean over period)
- Tair_2#
Air temperature at 2m
- Unit:
degC
- Aggregation:
Average (mean over period)
- Tair_bh#
Air temperature at building height
- Unit:
degC
- Aggregation:
Average (mean over period)
- Tair_hbh#
Air temperature at half building height
- Unit:
degC
- Aggregation:
Average (mean over period)
- Tair_ind#
Indoor air temperature
- Unit:
K
- Aggregation:
Average (mean over period)
- Textgrndflr#
External surface temperature of ground floor
- Unit:
K
- Aggregation:
Average (mean over period)
- Textroof#
External surface temperature of roof
- Unit:
K
- Aggregation:
Average (mean over period)
- Textwall#
External surface temperature of wall
- Unit:
K
- Aggregation:
Average (mean over period)
- Textwindow#
External surface temperature of window
- Unit:
K
- Aggregation:
Average (mean over period)
- Tindoormass#
Indoor mass temperature
- Unit:
K
- Aggregation:
Average (mean over period)
- Tintgrndflr#
Internal surface temperature of ground floor
- Unit:
K
- Aggregation:
Average (mean over period)
- Tintroof#
Internal surface temperature of roof
- Unit:
K
- Aggregation:
Average (mean over period)
- Tintwall#
Internal surface temperature of wall
- Unit:
K
- Aggregation:
Average (mean over period)
- Tintwindow#
Internal surface temperature of window
- Unit:
K
- Aggregation:
Average (mean over period)
- Twater_tank#
Water temperature in tank
- Unit:
K
- Aggregation:
Average (mean over period)
- Twater_vessel#
Water temperature in vessel
- Unit:
K
- Aggregation:
Average (mean over period)
- Vwater_tank#
Volume of water in tank
- Unit:
m3
- Aggregation:
Average (mean over period)
- Vwater_vessel#
Volume of water in vessel
- Unit:
m3
- Aggregation:
Average (mean over period)
- ws_10#
Wind speed at 10m
- Unit:
m s-1
- Aggregation:
Average (mean over period)
- ws_bh#
Wind speed at building height
- Unit:
m s-1
- Aggregation:
Average (mean over period)
- ws_hbh#
Wind speed at half building height
- Unit:
m s-1
- Aggregation:
Average (mean over period)