Tip
Need help? Please let us know in the SUEWS Community.
Please report issues with the manual on GitHub Issues (or use Report Issue for This Page for page-specific feedback).
Please cite SUEWS with proper information from our Zenodo page.
4.3.44. Drainage Parameters#
Parameters for surface water storage drainage.
Parameters:
- store_min#
Minimum water storage capacity
- Unit:
mm
- Default:
0.0
- store_max#
Maximum water storage capacity
- Unit:
mm
- Default:
None (optional)
- store_cap#
Current water storage capacity - the actual storage capacity available for surface water retention. This represents the depth of water that can be stored on or in the surface before drainage begins. For paved surfaces, this might represent depression storage; for vegetated surfaces, it includes canopy interception storage.
- Unit:
mm
- Default:
None (optional)
- drain_eq#
Drainage equation selection (0: linear, 1: exponential)
- Unit:
dimensionless
- Default:
0
- drain_coef_1#
Drainage coefficient 1 (rate parameter)
- Unit:
mm h-1
- Default:
None (optional)
- drain_coef_2#
Drainage coefficient 2 (shape parameter)
- Unit:
dimensionless
- Default:
None (optional)
- ref#
The
refparameter group is defined by the Reference Info structure.